Line 18: | Line 18: | ||
The module Switch has the standard fields 'Label', 'Device', 'Port', and 'Channel'. Further parameters can be arbitrarily chosen and will be presented in the field 'Paremeters'. How to creaete drivers and define custom user input fields is described on the page [[Device Class Programming]]. | The module Switch has the standard fields 'Label', 'Device', 'Port', and 'Channel'. Further parameters can be arbitrarily chosen and will be presented in the field 'Paremeters'. How to creaete drivers and define custom user input fields is described on the page [[Device Class Programming]]. | ||
=== Apply & Stop buttons === | === Apply & Stop buttons === | ||
In the | In the 'Test' section of the module, there are the button "Apply" and "Stop" that can be used to do basic communication tests with the driver. | ||
These buttons trigger a series of semantic standard functions so that each driver automatically supports these buttons if semantic standard functions are correctly filled. | These buttons trigger a series of semantic standard functions so that each driver automatically supports these buttons if semantic standard functions are correctly filled. | ||
Line 42: | Line 39: | ||
* connect | * connect | ||
* signout | * signout | ||
* poweroff | |||
* unconfigure | * unconfigure | ||
* deinitialize | * deinitialize | ||
* disconnect | * disconnect |
Revision as of 18:16, 24 March 2023
The Switch module is generic one that can be used to create and load instrument drivers that do not match to any of the more specific device modules.
Typical instruments
Typical instruments are ones where the main task is to apply a value rather than reading values.
- Motor
- Relais or switching matrix
- Lamp
- Digital or analog outputs
- Filter wheel
GUI
The Switch module has a section 'Configuration' that can be used to apply a value according to the current Sweep Mode. It can be used to apply a value and stop the instrument if no measurement is running in order to test the instrument or to apply a value to adjust the setup.
Device class programming
The module Switch has the standard fields 'Label', 'Device', 'Port', and 'Channel'. Further parameters can be arbitrarily chosen and will be presented in the field 'Paremeters'. How to creaete drivers and define custom user input fields is described on the page Device Class Programming.
Apply & Stop buttons
In the 'Test' section of the module, there are the button "Apply" and "Stop" that can be used to do basic communication tests with the driver. These buttons trigger a series of semantic standard functions so that each driver automatically supports these buttons if semantic standard functions are correctly filled.
Apply triggers the following functions:
- connect
- initialize
- configure
- poweron
- signin
- start
- apply
- disconnect
Because 'configure' is used, the parameters of the Parameter section are applied at the beginning. The sweep value that is applied in "apply" will be handed over from the field "Configuration" right next to the Apply button.
Stop triggers the following functions:
- connect
- signout
- poweroff
- unconfigure
- deinitialize