SweepEditor
The SweepEditor is a tool to create sweep values in a short time. Several modules such as Sweep, SMU, Spectrometer, or Switch have their own SweepEditor to create the sweep values of the module. Select "SweepEditor" in the field "Sweep value:" of the module to use it. In some modules, e.g. SMU, the SweepEditor is located in the tab "Sweep values".
Each row of the SweepEditor creates a list of values. The rows are read one after another and the lists of all used rows are appended to each other. At the end, the SweepEditor returns a single list of sweep values. The rows have no further meaning for the variation in the Sequencer.
The SweepEditor has the columns Loop, Start, End, Step/Points, Scaling, and Hold in s.
- Use the buttons "+" and "-" above the table to append a row or to remove the last row. You can add as many rows as needed.
- Rows can be moved by drag & drop of the handle (⠿) at the beginning of each row.
- Right-click into the table and select "Show sweep values" to display the resulting list of values. The context menu also offers "Add line" and "Remove last line".
All fields accept the parameter syntax {...}. Note that sweep values are created before the measurement, so measured values of other modules cannot be used here (see Parameter system).
Loop
The Loop value defines how often the values of the row are created. Loop = 0 means "don't use the row", whereas Loop = 1 means "use the row one time". Thus, you can use Loop to switch a row on and off. Used rows do not need to be at the top. They can also be at the bottom with unused rows in between. Loop values larger than 1 repeat the whole list of values of the row. The maximum Loop value is 1e6, and at least one row must have a Loop value larger than 0.
Start & End
Start and End value determine the start and the end of the list of values. If they are equal, a single value is generated. For logarithmic scaling, start and end value must both be non-zero and must have the same sign.
Step/Points and Scaling
The column Scaling defines how the number in Step/Points is used:
| Scaling | Meaning of Step/Points |
|---|---|
| Step width | Step width between adjacent values of a linear sweep. The step width must fit to start and end value, otherwise an error message suggests a matching step width or end value. |
| Points (lin.) | Number of values, linearly spaced between start and end value. |
| Points (log.) | Number of values, logarithmically spaced between start and end value. Use an integer. |
| Points per dec. | Number of logarithmically spaced values per decade, beginning at the start value. The end value is always included. |
A row can create at most 1e6 values.
In older versions, a CheckBox in the column Step/Points switched between linear and logarithmic sweeps. It has been replaced by the column Scaling.
Hold in s
Each value is held for the given time after it was applied to the device. After that hold time, the procedure goes ahead with the measurement. A hold time is beneficial to reach a steady state after applying e.g. a voltage before a current is finally read out. All modules of the branch in the sequencer wait during this hold time.
Example
The example sequence "SMU" (menu "Sequences" -> "Load Example" -> "Instrument") uses the SweepEditor of the SMU module with two rows. First, a linear sweep from -2 to 2 with a step width of 0.02 is performed. Each value is held for 0.02 s after applying before the measurement continues. After the first row is finished, the second row leads to a backward sweep from 2 to -2 with the same step width and hold time. This way, the SweepEditor performs a forward and backward sweep as used to characterize hysteresis.
Time dependent measurements
In order to measure at a certain value multiple times, just set Loop of the row to a high value and choose Start equal to End.
Memory measurements
There are several memory tests which can easily be created using the SweepEditor. For example, Read-Write-Read-Erase tests can be designed by using four rows which have only one value each. The entire repetition of this sequence of values can then be done within the sequencer using a Loop module where the number of repetitions can be entered.
Hysteresis test
Forward and backward sweeps as needed for a hysteresis test can be created by using two rows. Another possibility is to use three rows, so that the sweep starts and ends at 0, e.g. 0 to 2, 2 to -2, and -2 to 0. This is especially helpful if starting from a high positive or negative value could already destroy the device.
Stop time
Versions before 1.5.5.33 had a column "Stop [s]" to switch the devices of a branch to their stop values for a given time after each measurement point. This function is no longer supported. It can be replaced by using a SweepBox or the module ReadValues.