Sequencer procedure: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
The following gives an overview of the functions that are called in a [[Device Class]] in the sequencer procedure. | The following gives an overview of the functions that are called in a [[Device Class]] in the sequencer procedure. | ||
SweepMe! version 1.5 | SweepMe! version 1.5.4 or higher | ||
Before you need to know what a [[Root-To-Leaf]] (branch) is. | Before you need to know what a [[Root-To-Leaf]] (branch) is. |
Revision as of 13:14, 10 June 2020
The following gives an overview of the functions that are called in a Device Class in the sequencer procedure.
SweepMe! version 1.5.4 or higher
Before you need to know what a Root-To-Leaf (branch) is.
# at start of the sequencer connect() -> for all items: get and open a port object to communicate with a device initialize() -> for all items: set all value and configurations to make the device ready for a measurement # if a item of the sequencer starts its parameter variation signin() -> does nothing, but can be used to do something before the parameter variation starts # if a new branch is entered and the module was not part of the previous branch configure() -> changes the configuration of the device poweron() -> switches the device on # if a leaf of a Root-To-Leaf is reached # each function is done for all items of the branch before the next function is performed: start() -> prepare something before value is applied ---------------------------------------------------------------------------------------------- apply() -> set the new value to a device if supported reach() -> wait to reach the new value, start reaching a certain condition ---------------------------------------------------------------------------------------------- sleephold() -> sleep the hold time while the value is applied to the device ---------------------------------------------------------------------------------------------- adapt() -> adapt the measurement devices to the new conditions adapt_ready() -> make sure all device have adapted to the new conditions trigger_ready() -> make devices ready to be triggered trigger() -> deprecated: will be continued for a while ---------------------------------------------------------------------------------------------- measure() -> initiate/trigger a measurement, nothing else request_result() -> request a result from the device buffer read_result() -> read a result from the port buffer ---------------------------------------------------------------------------------------------- process_data() -> process the measured data after the measurement itself has finished call() -> mandatory: return values to SweepMe! ---------------------------------------------------------------------------------------------- process() -> deprecated: will be continued for a while finish() -> clean up before the next measurement starts ---------------------------------------------------------------------------------------------- sleepstop() -> sleep the stop time while the device is set to its idlevale # if a branch is left and the module is not part of the next branch poweroff() -> for all items: switches the device off unconfigure() -> set value to idlevalue and apply() it # if a item of the sequencer finishs its parameter variation signout() -> does nothing, but can be used to do something after the parameter variation # at end for all items of the sequencer deinitialize() -> for all items: reset the status for any other user of the equipment disconnect() -> for all items: closes the port object