Line 2: | Line 2: | ||
SweepMe! version 1.5.4 or higher | SweepMe! version 1.5.4 or higher | ||
# at start of the sequencer | # at start of the sequencer | ||
Line 20: | Line 18: | ||
[[start()]] -> prepare something before value is applied | [[start()]] -> prepare something before value is applied | ||
---------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------- | ||
[[apply()]] -> set the new value to a device if supported | [[apply()]] -> set the new value to a device if supported | ||
[[reach()]] -> wait to reach the new value, start reaching a certain condition | [[reach()]] -> wait to reach the new value, start reaching a certain condition | ||
---------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------- | ||
wait hold time -> sleep any hold time while the setvalues are applied | |||
---------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------- | ||
[[adapt()]] -> adapt the measurement devices to the new conditions | [[adapt()]] -> adapt the measurement devices to the new conditions | ||
Line 35: | Line 33: | ||
---------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------- | ||
[[process_data()]] -> process the measured data after the measurement itself has finished | [[process_data()]] -> process the measured data after the measurement itself has finished | ||
[[call()]] -> '''mandatory''': return values to SweepMe! | [[call()]] -> '''mandatory''': return values to SweepMe! as defined by self.variables | ||
---------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------- | ||
[[process()]] -> deprecated: will be continued for a while | [[process()]] -> deprecated: will be continued for a while | ||
[[finish()]] -> clean up before the next measurement starts | [[finish()]] -> clean up before the next measurement starts | ||
---------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------- | ||
wait stop time -> deprecated from 1.5.5.: sleep any stop time while time while the devices are set to their idlevalues | |||
# if a [[branch]] is left and the module is not part of the next branch | # if a [[branch]] is left and the module is not part of the next branch |
Revision as of 13:18, 10 June 2020
The following gives an overview of the functions that are called in a Device Class in the sequencer procedure.
SweepMe! version 1.5.4 or higher
# at start of the sequencer connect() -> for all items: get and open a port object to communicate with a device initialize() -> for all items: set all value and configurations to make the device ready for a measurement # if a item of the sequencer starts its parameter variation signin() -> does nothing, but can be used to do something before the parameter variation starts # if a new branch is entered and the module was not part of the previous branch configure() -> changes the configuration of the device poweron() -> switches the device on # if a leaf of a Root-To-Leaf is reached # each function is done for all items of the branch before the next function is performed: start() -> prepare something before value is applied ---------------------------------------------------------------------------------------------- apply() -> set the new value to a device if supported reach() -> wait to reach the new value, start reaching a certain condition ---------------------------------------------------------------------------------------------- wait hold time -> sleep any hold time while the setvalues are applied ---------------------------------------------------------------------------------------------- adapt() -> adapt the measurement devices to the new conditions adapt_ready() -> make sure all device have adapted to the new conditions trigger_ready() -> make devices ready to be triggered trigger() -> deprecated: will be continued for a while ---------------------------------------------------------------------------------------------- measure() -> initiate/trigger a measurement, nothing else request_result() -> request a result from the device buffer read_result() -> read a result from the port buffer ---------------------------------------------------------------------------------------------- process_data() -> process the measured data after the measurement itself has finished call() -> mandatory: return values to SweepMe! as defined by self.variables ---------------------------------------------------------------------------------------------- process() -> deprecated: will be continued for a while finish() -> clean up before the next measurement starts ---------------------------------------------------------------------------------------------- wait stop time -> deprecated from 1.5.5.: sleep any stop time while time while the devices are set to their idlevalues # if a branch is left and the module is not part of the next branch poweroff() -> for all items: switches the device off unconfigure() -> set value to idlevalue and apply() it # if a item of the sequencer finishs its parameter variation signout() -> does nothing, but can be used to do something after the parameter variation # at end for all items of the sequencer deinitialize() -> for all items: reset the status for any other user of the equipment disconnect() -> for all items: closes the port object