This page describes the tools of the SweepMe! MCP server in SweepMe! 1.6.1.7. AI applications read these descriptions automatically, so you do not need them to use SweepMe! with AI. They help to understand what an assistant can do and to write your own MCP clients. How to connect an AI application is described in AI applications.
Typical workflow
- load_sequence: load the sequence file of your measurement.
- set_folder and set_filename: choose where the data will be saved. Loading a sequence restores the folder and file name stored in it, so set them after loading.
- start_run: start the measurement. The tool returns immediately.
- wait_for_completion: wait until the run has finished.
- get_all_measurement_values or get_measurement_value: read the latest values, or read the saved data file (see Loading data files).
The server sends this workflow to the AI application as part of its instructions when the connection is established.
Tools
All tools act on the SweepMe! instance that serves the port, and on the sequence that is currently loaded. Values are returned as text or JSON.
Status and info
| Tool | Arguments | Description |
|---|---|---|
| get_status | none | Running and paused state, elapsed time, progress, branch index, version, and whether the data has been saved since the last run started. |
| get_sweepme_version | none | Version of the running SweepMe! instance, e.g. "1.6.1.7". |
| get_instance_info | none | Process id, executable, SweepMe! version, start time of the interface, URL, and the currently loaded sequence. Use it to check which instance you control if several SweepMe! instances are open. |
| get_measurement_progress | none | Progress of the current run: point, number of points and progress per branch, if available. |
| get_debug_log | lines (integer, default 100), since_last_run (boolean) |
Last lines of the debug log. Useful to find the reason for an error during a run. |
Measurement control
| Tool | Arguments | Description |
|---|---|---|
| start_run | none | Starts the measurement of the loaded sequence and returns immediately. |
| stop_run | none | Stops the running measurement. |
| pause_run | none | Pauses the running measurement. |
| resume_run | none | Resumes a paused measurement. |
| skip_current_branch | none | Skips the current branch of the Sequencer and continues with the next one. |
| wait_for_completion | timeout_s (number, default 600), poll_interval_s (number, default 2) |
Waits until the run has finished and returns completed, timed_out and the final status. If the timeout is reached, the tool returns with timed_out = true while the run continues, so the assistant can call it again.
|
Measurement values
| Tool | Arguments | Description |
|---|---|---|
| list_measurement_parameters | none | All parameter keys that are currently registered, e.g. SMU1_Voltage_V. The keys depend on the modules of the loaded sequence, see Parameter system.
|
| get_measurement_value | key (string, required) |
Latest value of one parameter. |
| get_all_measurement_values | none | Latest values of all parameters as a dictionary. |
Only the latest values are returned. The complete data of a run is in the data files, see Saving data.
Sequences and data files
| Tool | Arguments | Description |
|---|---|---|
| load_sequence | filepath (string, required) |
Loads a sequence (.seq) or a legacy setting (.set). Use the full file path. Only possible while no measurement is running.
|
| get_current_setting | none | File path of the loaded sequence. |
| set_filename | file_name (string, required) |
File name for the data of the next run, without folder. |
| set_folder | folder (string, required) |
Name of the folder for the data, as in the field Folder of the Save Bar. It is created inside the measurement folder of the current profile, so pass a folder name, not a full path (the character ":" is not allowed). |
| save_data | none | Saves the data of the last run with the current folder and file name. |
Driver and module versions
| Tool | Arguments | Description |
|---|---|---|
| get_driver_version | driver_name (string, required) |
Active version of a driver. |
| get_available_driver_versions | driver_name (string, required) |
Installed versions of a driver. |
| set_driver_version | driver_name, version_string (strings, required) |
Activates a version, e.g. a date like "2024-01-01" or "custom". Only possible while no measurement is running. |
| get_module_version | module_name (string, required) |
Active version of a module. |
| get_available_module_versions | module_name (string, required) |
Installed versions of a module. |
| set_module_version | module_name, version_string (strings, required) |
Activates a version of a module, e.g. "1.6.1.1" or "custom". |
See Version manager for the meaning of the versions.
Advanced
| Tool | Arguments | Description |
|---|---|---|
| list_commands | only_triggerable (boolean, default true) |
Lists the commands of SweepMe!, including the functions that modules and drivers of the loaded sequence register, e.g. actions of CustomFunction scripts. With true, only commands without arguments are listed. |
| call_command | key (string, required), args (list), kwargs (dictionary) |
Calls a command from list_commands. The commands are the same as for the other interfaces. |
| close_sweepme | none | Closes SweepMe! without asking about unsaved changes. Only possible while no measurement is running. Assistants are told to use it only when asked to. |
Technical details
- Transport: streamable HTTP. Requests are sent with POST to
/mcp. The server is stateless and does not offer a GET stream. - Supported MCP protocol versions: 2025-06-18, 2025-03-26 and 2024-11-05.
- Server name:
sweepme. - Requests from web pages of other websites are rejected (HTTP 403). Desktop applications and command line tools send no such header and are accepted.
- The server has no authentication. See Authentication and security.